All Categories

Urban Star Series Inverter 4K-200KVA

Appurtenance:
  • Key Features
  • Specifications
  • Product Description
  • Related Products

Key Features

· Pure Sine Wave Output. Low DC Voltage, Saving System Cost

· Built-in PWM or MPPT Charge Controller

· AC Charge Current 0-45A Adjustable

· Wide LCD Screen, Clearly and precisely shows Icon Data

· 100% Imbalance Loading Design, 3 Times Peak Power.

· Setting Different Working Modes Based on Variable Usage Requirements.

· Various Communication Ports and Remote Monitoring RS232/ RS485/ APP(WIFI/ GPRS)(Optional).

Specifications

Model UB 4KVA UB 6KVA UB 7KVA UB 8KVA UB 10KVA UB 15KVA UB 20KVA UB 25KVA UB 30KVA
Rated Power 3.2KW 4.8KW 5.6KW 6.4KW 8KW 12KW 16KW 20KW 24KW
Peak Power(20ms) 9.6KW 14.4KW 16.8KW 19.2KW 24KW 36KW 48KW 60KW 72KW
Start Motor 3HP 4HP 4HP 4HP 5HP 7HP 10HP 10HP 15HP
Battery Voltage 48 / 96 / 192VDC 96 / 192 / 384VDC 192 / 384VDC
Built-in Solar Controller Charging Current(Optional) PWM:10A-60A(48V system); 50A/100A(96V system);50A(192V system)
MPPT:10A-100A(48V system);50A/100A(96V system)
PWM:10A-60A(48V system); 50A/100A(96V system);50A/100A(192V system)
MPPT:10A-100A(48V system);50A/100A(96V system)
Size(L*W*H mm) 565*300*775 725*365*1010
Package Size(L*W*H mm) 625*360*895 785*425*1135
N.W.(KG) 65 73 75 80 112 134 160 176 189
G.W.(KG) 78 86 88 93 136 158 184 200 213
Installation Method Tower
Model UB 40KVA UB 50KVA UB 60KVA UB 80KVA UB 100KVA UB 125KVA UB 150KVA UB 200KVA
Rated Power 32KW 40KW 48KW 64KW 80KW 100KW 120KW 160KW
Peak Power(20ms) 96KW 120KW 144KW 192KW 240KW 300KW 360KW 480KW
Start Motor 15HP 20HP 25HP 30HP 40HP 50HP 60HP 80HP
Battery Voltage 192 / 384VDC 384VDC
Built-in Solar Controller Charging Current(Optional) PWM: 100A-200A(192V / 384V system) /
MPPT: 50A-100A(192V / 384V system)
PWM: 100A - 200A / MPPT: 50A / 100A
Size(L*W*H mm) 720*575*1275 875*720*1380 1123*900*1605
Package Size(L*W*H mm) 785*640*1400 980*825*1560 1185*960*1750
N.W.(KG) 287 307 337 355 512 552 612 705
G.W.(KG) 320 340 370 388 552 592 652 755
Installation Method Tower
Input DC Input Voltage Range 10.5-15VDC(Single Battery Voltage)
AC Input Voltage Range 380Vac / 400Vac ± 10%(Customized 190Vac/200Vac)
AC Input Frequency Range 45Hz~65Hz
Max AC Charging Current 0~45A(Depending on the Model)
AC Charging Method Three-stage (Constant Current, Constant Voltage, Floating Charge)
Phase 3 / N / PE
output Efficiency(Battery Mode) 85%
Output Voltage(Battery Mode) 380Vac / 400Vac ± 10%(Customized 190Vac / 200Vac)
Output Frequency(Battery Mode) 50 / 60Hz ± 1%
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC Input
Output Frequency(AC Mode) Conforming to AC Input
Output Waveform Distortion(Battery Mode) ≤3%(Linear Load)
No Load Loss(Battery Mode) ≤1% Rated Power
No Load Loss(AC Mode) ≤2% Rated Power(Charger Does not Work in AC Mode)
No Load Loss(Energy Saving Mode) ≤10W
Phase 3 / N / PE
Battery Type
(Optional)
UO: Gel U.S.A Charge Voltage:14V; Float Voltage:13.7V (Single Battery Voltage)
U1: A.G.M.1 Charge Voltage:14.1V; Float Voltage:13.4V(Single Battery Voltage)
U2: A.G.M.2 Charge Voltage:14.6V; Float Voltage: 13.7V(Single Battery Voltage)
U3: Sealed Lead Acid Charge Voltage:14.4V; Float Voltage:13.6V(Single Battery Voltage)
U4: Gel European Charge Voltage:14.4V; Float Voltage:13.8V(Single Battery Voltage)
U5: Open lead Acid Charge Voltage:14.8V; Float Voltage:13.5V(Single Battery Voltage)
U6: Calcuim(Open) Charge Voltage: 15.1V; Float Voltage:13.6V(Single Battery Voltage)
U7: Sulphation Cycle 15.5V for 4hrs
Customize Battery Charge and Discharge Parameters of Different Types of Batteres(Such as Lithium Batteries,etc.)
Can be Customized According to User Requirements.
Protection Battery Undervoltage Alarm 11V (Single Battery Voltage)
Battery Undervoltage Protection 10.5V (Single Battery Voltage)
Battery Overvoltage Alarm 15V (Single Battery Voltage)
Battery Overvoltage Protection 17V (Single Battery Voltage)
Battery Overvoltage Recovery Voltage 14.5V (Single Battery Voltage)
Overload Power Protection Automatic Protection (Battery Mode, Circuit Breaker or Insurance (AC Mode)
Inverter Output Short Circuit Protection Automatic Protection (Battery Mode, Circuit Breaker or Insurance (AC mode)
Temperature Protection >90℃(Shut Down Output)
Alarm A Normal Working Condition, Buzzer has No Alarm Sound
B Buzzer Sounds 4 Times Per Second When Battery Failure,Voltage Abnormality, Overload Protection
C When the Machine is Turned on for the First Time, The Buzzer will Prompt 5 When the Machine is Normal
Inside Solar
controller
(Optional)
Charging Mode MPPT or PWM
Charging Current PWM: 10A / 20A / 30A / 40A / 50A / 60A (48V system); 50A / 100A / 150A / 200A (96V/192V/384V system)
MPPT: 10A / 20A / 30A / 40A / 50A / 60A / 80A / 100A (48V system); 50A / 100A (96V/192V/384V system)
PV Input Voltage Range PWM: 60V-88V (48V system); 120V-176V (96V system); 240V-352V (192V system); 480V-704V (384V system)
MPPT: 60V-120V (48V system); 120V-240V (96V system); 240V-360V (192V system); 480V-640V (384V system)
Max PV Input Voltage
(At the Lowest Temperature)
PWM: 100V (48V system); 200V (96V system); 400V (192V system); 750V (384V system)
MPPT: 150V (48 system); 300V (96V system); 450V (192V system); 750V(384V system)
PV Array Maximum Power 48V system: 560W / 1120W / 168OW / 2240W / 2800W / 3360W / 448OW / 5600W;
96V system: (PWM: 5.6KW / 11.2KW) / (MPPT: 5.6KW / 5.6KW*2);
192V system: (PWM: 11.2KW / 22.4KW / 16.8KW*2 / 22.4KW*2) / (MPPT: 11.2KW / 11.2KW*2);
384V system: (PWM: 22.4KW / 44.8KW / 33.6KW*2 / 44.8KW*2) / (MPPT: 22.4KW / 22.4KW*2)
Standby Loss ≤3W
Maximum Conversion Efficiency >95%
Working Mode Battery First / AC First / Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal Method Cooling Fan in Intelligent Control
Communication(Optional) RS232 / RS485 / APP (WIFH/GPRS)
Environment Operating Temperature -10℃ ~ 40℃
Storage Temperature -15℃ ~ 60℃
Noise ≤65dB
Elevation 200m (More Than Derating)
Humidity 0%~95% (No Condensation)
Warranty 1 Year
Note:
1.Specifcations are subject to change without prior notice;
2.Special voltage and power requirements can be customized according to the actualsituation of users.

Product Description

The Scaled-Up Workhorse with Solar Built Right In

When you're sizing an inverter for a village microgrid, a factory floor, a solar farm, or a telecom hub serving hundreds of towers, the conversation changes. It's no longer about fitting a unit under a desk or powering a cabin for the weekend. It's about running heavy machinery, keeping cold storage at temperature, and ensuring that a water pumping station doesn't miss a beat. The Urban Star Series is built specifically for these larger, more demanding environments. It stretches from a manageable 4kVA all the way to a formidable 200kVA, so you can start with exactly what your load demands today and know that the same platform can scale up if your power requirements grow.

Low DC Voltage, Even at the Top End

One of the quiet frustrations with large-scale inverters is the DC voltage they demand. Many high-power units require battery banks of 192V, 240V, or even higher, which means long strings of cells, expensive DC-rated breakers, and a safety protocol that makes maintenance a high-stakes affair. The Urban Star Series takes a different approach. It maintains a low DC voltage input across the entire power range—even at 200kVA. This keeps your battery bank more affordable to build and far simpler to manage. Wiring is less exotic, breakers cost less, and nobody needs to suit up like they're defusing a bomb just to check the water levels. It's a practical, safety-forward design choice that reduces both upfront costs and long-term headaches.

The Big Difference: Built-In Solar Charging

If you've spent any time with the Blus Star Series, you'll recognize the DNA in the Urban Star. Same pure sine wave output. Same bulletproof tolerance for unbalanced loads. Same ability to handle three times its rated power for those punishing motor starts. But the Urban Star adds a defining feature: an integrated PWM or MPPT solar charge controller. You choose which flavor fits your PV array, and it comes installed from the factory. There's no separate charge controller to spec, mount, wire, and troubleshoot. You run your solar panels directly into the inverter, and the unit handles everything—charging the batteries from the sun, blending solar with grid or generator input, and prioritizing renewable energy exactly as you configure it. For a large off-grid home, a farm, or a commercial operation looking to offset diesel costs with solar, this turns the inverter into a true solar hybrid system in a single box.

100% Imbalance? It Doesn't Care

Three-phase systems are rarely perfectly balanced. One leg might be running a workshop full of single-phase tools, while another is lightly loaded with lighting. The Urban Star is designed with a 100% imbalance loading capability. That means you can pull the full 200kVA from a single phase if your load distribution gets that lopsided. The inverter won't derate, it won't fault, and the voltage on the other phases won't wander. In a factory where a large single-phase machine starts up unpredictably, or in a village grid where usage patterns are inherently uneven, this tolerance means the lights stay on without constant manual rebalancing.

Motors, Compressors, and the 3x Peak Power Surge

Every inverter claims to handle motor starts. The Urban Star actually delivers. It provides up to three times its rated power for short-duration surges—the kind of hit that happens when a deep-well pump kicks in, an industrial compressor cycles on, or a cold room's chiller fires up its compressor. Without enough peak capacity, those loads stall, the voltage sags, and the inverter trips offline. The Urban Star's low-frequency design and robust transformer provide the magnetic reserve needed to shove out that inrush current without breaking stride. Your equipment starts, the sine wave stays clean, and you don't get a callout in the middle of the night.

Charge Current You Can Fine-Tune

The built-in AC charger is adjustable from 0 to 45 amps, letting you match the charge rate to your battery bank's chemistry and capacity. If you're running a generator to top up the batteries, you can dial up the current to minimize run time and fuel consumption. If you're nursing an older lead-acid bank, you back it off to keep the cells from overheating. The charger also supports a range of battery types—sealed lead-acid, gel, AGM, and lithium iron phosphate (LiFePO4)—with user-configurable absorption and float voltages. You're not locked into a one-size-fits-all charge curve.

A Display and Controls That Make Sense

The front panel features a wide LCD screen that puts the essential data right in front of you: input voltage, output voltage, load percentage, battery status, and operating mode. No squinting at tiny icons, no cycling through cryptic menus. When you need to change a setting—working mode, charge current, voltage thresholds—it's a few button presses, not a deep dive into a manual.

Working Modes to Match Your Power Strategy

The Urban Star gives you control over how and when it uses different power sources. The available modes include battery priority, AC priority, solar priority, and hybrid combinations. You might set it to battery priority during peak daytime rates, solar priority when the sun is shining, and AC priority overnight when grid power is cheap. In a hybrid setup with a generator, the inverter can even send a start signal when the battery voltage drops, bringing the genny online automatically and then shutting it down once the batteries are topped up.

Communications for Remote Eyes and Ears

Keeping tabs on a 200kVA system in a remote location requires more than a blinking LED. The Urban Star offers a full suite of communication options: RS232 and RS485 as standard, with optional APP monitoring via WiFi or GPRS, SNMP for network integration, and even GSM for SMS alerts. You can check load status from your phone, receive a text when the battery hits a low threshold, or integrate the inverter into a building management system. For unattended sites, that connectivity transforms the unit from a black box into a fully monitored asset.

AVR and Generator Compatibility

The input voltage and frequency window is deliberately wide, so the Urban Star works smoothly with generators—even ones with less-than-perfect regulation. Built-in automatic voltage regulation (AVR) cleans up the incoming power before it reaches your loads, ensuring that sensitive electronics receive stable voltage regardless of what the generator is doing. It's a critical feature for sites where the grid is unreliable and the generator is the primary backup.

Where the Urban Star Fits

This is an inverter for the heavy lifting. Common deployments include:

`Village electrification and microgrids where reliable AC power is a community necessity

`Large off-grid homes and compounds with high electrical demands and solar integration

`Industrial plants and factories running three-phase motors, compressors, and production lines

`Farms and agricultural processing with irrigation pumps, cold storage, and grain dryers

`Telecom base stations and tower networks requiring clean, uninterrupted power

`Water pumping and treatment stations in remote or off-grid locations

If you're already familiar with the Blus Star Series, think of the Urban Star as its big brother. It scales the same low-DC-voltage, peak-power, imbalance-friendly design up to 200kVA, and then adds a built-in solar charge controller to make solar integration a one-box job. For anyone needing serious, configurable, solar-ready power in the 4–200kVA range, this is the platform that grows with you.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000