33RM Series Rack Mount Online UPS 10KVA-60KVA

Appurtenance:
  • Key Features
  • Technical Specification
  • Product Description
  • Related Products

Key Features

.True double-conversion

.LCD screen auto-rotation with Rack position (only for 10K-20K models)

.DSP technology guarantees high performance

.Output power factor 1. Active power factor correction in all phases

.50Hz/60Hz frequency converter mode

.ECO mode operation for energy saving (ECO)

.Emergency power off function (EPO)

.Generator compatible

.Supports dual AC inputs

.3-stage extendable charging design for optimized battery performance

. Adjustable battery numbers for long-run model

.Parallel operation with common battery

.Optional isolation transformer offers full isolation and complete common mode noise rejection

Technical Specification

MODEL 33RM 10KL 33RM 20KL 33RM 30KL 33RM 40KL 33RM 60KL
PHASE 3-phase in/3-phase ou t
CAPACITY 10KVA/10KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW
PARALLEL CAPABILITY 4
INPUT
Nominal Voltage 3x 400 VAC (3Ph+N)
Valtage Range 190-520 VAC (3-phase) @50% load, 305-478 VAC (3-phase)@100% load
Frequency Range 46-54 Hz or 56-64Hz
Power Factor ≥0.99 @100% load
OUTPUT
Output Voltage 3x360/380/ 400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ±1%
Frequency Range (Synchronized Range) 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ±0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤ 2% THD (Linear Load). s 5% THD (Non-linear Load)
Transfer Time AC mode to Battery mode zero
Inverter to Bypass zero
Wave form (Batt. Mode) Pure Sine Wave
Overload AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 mint;>150% immediately
Battery Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min:>150% immediately
EFFICIENCY
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
BATTERY
Battery Type Depending on the applications
Numbers 20 pcs
Charging Current (max) 1A-12A(Adjustable) 1A~16A(Adjustable) 1A-18A(Adjustable)
Charging Voltage +/-13.65 VDCxN
(N-10)
+/-13.65 VDC x N(N=16-20)
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fauit Continuously sounding
PHYSICAL
Dimension,D*W"H(mm) 680*438*133[3U] 680*438*133 [3U] 797"438*176[4U]
Net Weight (kgs) 26 28 40 40 45
ENVIRONMENT
Operation Temperture 0-40℃
Operation Humidity <95% and non-condersing
Noise Level Less than 62dB @1
Meter
Less than 65dB @ 1
Meter
Less than 65dB @1
Meter
Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® family,Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
*When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%.
*Product specifications are subject to change without further notice

Product Description

A Three-Phase Rack UPS That Doesn't Make You Work Around It

If you've ever tried to read a rack-mounted UPS display while your neck is twisted at an angle that'd make a chiropractor wince, you'll get why the 33RM Series on the 1020kVA models starts with the screen. It auto-rotates. Mount the unit vertically in a tower orientation, the LCD flips. Lay it flat in a rack shelf, it flips again. No menu diving to rotate the display, no squinting at sideways text during a midnight alarm. It's such a simple fix, you wonder why every rack UPS doesn't do it.

But the 33RM is more than a clever screen. It's a true double-conversion online UPS, scaling from 10 to 60kVA, built for standard 19-inch racks in data centers, server rooms, and industrial enclosures.

Real Power, No Derating Games

Output power factor is 1.0. A 60kVA unit actually delivers 60kW. That's not a paper specit means you can fill the rack with modern servers that run near-unity power factor and actually use all the capacity you paid for. DSP digital control keeps the output voltage and frequency locked steady, regardless of what the grid does. Zero transfer time, always regenerating a clean sine wave.

Dual Inputs and Generator Tolerance Built In

The 33RM comes standard with dual AC inputs. You can feed it from two independent utility sources, or one utility and one backup generator. If the primary feed drops, the UPS draws from the secondary without a hiccup. There's no add-on module to buy, no external switchgear to figure out.

Generator compatibility is handled by a wide input windowthe UPS accepts the kind of loose voltage and frequency that smaller or older gensets produce without constant battery-cycling. It syncs, cleans the power through double conversion, and keeps the load safe. And if you need to run equipment designed for a different grid frequency, there's a frequency converter mode (50Hz to 60Hz or vice versa) built right in.

ECO Mode When the Grid Behaves

For energy savings, you can switch to ECO mode, which bypasses the double conversion while keeping the inverter spinning and ready. The moment the utility wobbles, it snaps back to online mode. In a facility with relatively stable power, that shaves a few points off the electric bill without giving up protection.

Emergency Power Off and Battery Management

EPO is standarda hard-wired shutdown that kills output instantly when safety demands it.

On the battery side, the charger uses a three-stage extendable design. It conditions the batteries properly, and if you need more runtime, you can adjust the number of battery cells to match your specific backup requirements. No rigid string lengths. For long-runtime configurations, that flexibility saves you from overbuying or under-sizing.

Parallel for Redundancy, Common Battery for Savings

You can parallel multiple 33RM units for N+X redundancy or capacity. And here's where it saves real money: the paralleled units can share a single common battery bank. Instead of buying and maintaining separate battery cabinets for each UPS, you invest in one pool. Fewer cells, less floor space, lower total cost.

Optional Isolation Transformer

Some sites need complete electrical separationmedical imaging suites, sensitive lab instruments, legacy industrial gear that's prone to ground-loop noise. The 33RM offers an optional internal or external isolation transformer. You get galvanic isolation without stepping up to a massive, low-frequency transformer-based UPS. It's there if you need it, invisible if you don't.

Active PFC Keeps the Wiring Happy

Active power factor correction on all three phases pushes input PF above 0.99. The UPS pulls current cleanly, in phase with the voltage, reducing harmonic pollution that can overheat neutrals and trip breakers in older buildings.

Where the 33RM Fits

This is a rack-mount three-phase UPS for mid-size data centers, server rooms, telecom exchanges, and industrial racks. At 1020kVA, the auto-rotating display is a genuine quality-of-life upgrade for anyone who has to stand in front of the rack. At 3060kVA, it's a dense, scalable power plant in a 19-inch chassis. Dual inputs, common battery parallel, frequency conversion, and optional isolationthe 33RM covers the range from straightforward backup to tightly specified mission-critical setups.

And yes, the screen flips. It's a small thing. But when you're the one staring at it at 3 a.m., small things matter.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000