If you’ve ever plugged a piece of expensive network gear into an outlet that turns out to be wired backwards—line and neutral swapped—you know the sinking feeling when nothing works right and you can’t figure out why. It’s common enough in older buildings and renovated offices that you’d think UPS manufacturers would build in a way to flag it. Most don’t. The RT Series does.
.19 inches standard structure design of rack mount,compact structure and sinusoidal wave output provide best power supply guarantee.
.0 conversion time between mains mode and battery mode.
.It has detection function of input zero line and fire line.
.Having voltage surge protection function and strong anti-interference function.
.Equipped with correction function of input power factor
.Original matching battery
.Supporting mobile smart monitoring card,users can real-time monitor every data of the UPS by mobile APP.
| Model | RT1K | RT1KL | RT2K | RT2KL | RT3K | RT3KL | RT6K | RT6KL | RT10K | RT10KL | ||
| Input | Rated Capacity | 1KVA/900W | 2KVA/1800W | 3KVA/2700W | 6KVA/5400W | 10KVA/ 9000W | ||||||
| Voltage Range | 90-285 1P2W+G | 120-275 1P2W+G | ||||||||||
| Frequency | 40~70 Hz (Settable) | |||||||||||
| Power factor | 20.99 | |||||||||||
| Output | Voltage | 220Vac(1±2%) 1P2W+G | ||||||||||
| Rated Current | 4.5A | 9.1A | 13.6A | 27A | 45A | |||||||
| Output Power Factor | 46-54Hz synchronize with mains; 50Hz(Mains power between 40-46Hz and 54-60Hz);50Hz (Battery) | |||||||||||
| Output Power Factor | 0.9 | |||||||||||
| Output Harmonic Wave | 54% (Full R Load) | s3% (Full R Load) | ||||||||||
| Crest Factor | 3:1 | |||||||||||
| Output Overload (Normal Mode) |
Overload pre-warning: 100%±2%<Load Output warning: Convert to bypass mode and alarm after 30 mins, 102%±2% ≤ Load≤ 110%±2% Output warning:Convert to bypass mode and alarm after 10 mins, 110% ±2% Output warning:Convert to bypass mode and alarm after 30s, 130% ± 2% Convert to bypass mode and alarm after 200ms, Load>150%±2% |
105%±5%<Loads125%±5%: Convert to bypass output and alarm after min; 125%±5%<Load≤135%±5%: Convert to bypass output and alarm after 30s; Load>135%±5%: Convert to bypass output and alarm after 300ms. |
||||||||||
| Cormversion time between Mains Power and Battery |
0ms | |||||||||||
| Efficiency | ≥90% Normal Mode | ≥92% | ||||||||||
| Battery | Rated Voltage | 24VDC | 36VDC | 48VDC | 72VDC | 72VDC | 96VDC | 192VDC | ||||
| Quantity | Internal 12V7AH*2PCS |
External | Internal 12V7AH*4PCS |
External | Internal 12V7AH*6PCS |
External | Internal 12V7AH*16PCS |
External | Internal 12V7AH*16PCS |
External | ||
| Charging Current | 1A | 6.5A | 1A | 5.5A | 1A | 5.5A | 1A | 5.5A | 1A | 5.5A | ||
| Working Temperatures(℃) | 0-40℃ | |||||||||||
| Working Humidity | 20%~95% (Non-condensing) | |||||||||||
| Altitude | <1500m | |||||||||||
| Noise | ≤ 55dB | |||||||||||
| Communication | RS232 | |||||||||||
| Machine Size (L"W"H) mm | 400*482.6*88 | 550*482.6*88 | 400*482.6*88 | 665*482.6*132.5 | ||||||||
| Net Weight(kg) | 10.5 | 6.5A | 15.5 | 7.5 | 22 | 7.8 | 19 | 20 | 20.5 | 21.5 | ||
| *Specifications are subject to change without prior notice. | ||||||||||||
Rack-Ready, App-Savvy, and Smart Enough to Spot a Miswired Outlet
If you've ever plugged a piece of expensive network gear into an outlet that turns out to be wired backwards—line and neutral swapped—you know the sinking feeling when nothing works right and you can't figure out why. It's common enough in older buildings and renovated offices that you'd think UPS manufacturers would build in a way to flag it. Most don't. The RT Series does.
It's a 19-inch rack-mount online UPS that checks the input wiring the moment you connect it. If the outlet has its line and neutral reversed, the UPS tells you. No multimeter, no electrician, no mystery faults that only show up during a power event. That feature alone has saved countless hours of head-scratching on installation day.
True Double Conversion, Zero Transfer Time
Behind that clever detection sits a genuine online double-conversion UPS. The inverter runs continuously, regenerating a pure sine wave from the DC bus. Your servers, switches, and storage arrays never touch raw utility power. When the grid fails, there's no switch to throw, no gap to cover—the battery feeds the DC bus and the output sine wave doesn't twitch. For a full rack of critical IT gear, that's the baseline you want.
Clean Power In, Even When the Wiring Isn't Perfect
The RT Series takes the unpredictability of real-world electrical installations seriously. Besides the polarity check, it packs voltage surge protection and strong anti-interference filtering. If you're sharing a circuit with noisy equipment—elevator motors, large HVAC units, production machinery—the UPS strips out the spikes and high-frequency noise before they reach your gear. Input power factor correction keeps the current draw clean and efficient, so you're not adding harmonic garbage back onto the building's wiring.
Original Batteries, No Shopping Around
The RT Series ships with matching original batteries already installed. You don't have to source a separate battery pack, check compatibility, or wrestle with wiring harnesses. Unbox it, rack it, connect the input and output, and you're up and running. For IT teams managing multiple sites, that kind of out-of-the-box simplicity cuts deployment time down to almost nothing.
Mobile Monitoring That Actually Works
Here's the modern touch that makes this UPS feel like it was designed in this decade: it supports an optional mobile smart monitoring card. Pop the card into the slot, install the app on your phone, and you can check every parameter—load percentage, battery status, input/output voltage, alarm logs—from anywhere with a data connection. No need to fire up a laptop, VPN into the network, or walk to the server room at 2 a.m. just to see if the UPS is still on battery. The app gives you real-time visibility in your pocket.
Where the RT Series Belongs
This is a UPS for standard IT racks in environments where uptime matters and remote visibility makes life easier:
`Server rooms and data center cabinets
`Network racks in branch offices, retail stores, or clinics
`Telecom shelters and base stations
`Banking and financial services equipment (ATMs, branch servers)
`Hospital nursing stations and diagnostic imaging racks
`Government offices and traffic management systems
`Security control rooms and CCTV recording racks
It's not trying to be an industrial ruggedised unit—that's what the RS Series handles. The RT Series is purpose-built for standard IT environments where rack density, clean power, and easy remote management are the priorities. The polarity detection is a bonus that solves a specific, annoying problem; the rest of the unit is a straightforward, well-built online UPS that fits exactly where you expect it to.
The Practical Choice for Rack Deployments
If you've ever been burned by a UPS that was too deep for the rack, too loud for the office, or too dumb to tell you the outlet was wired wrong, the RT Series is a refreshing change. It's a true online UPS, rack-mountable in a standard 19-inch frame, with pure sine wave output, zero transfer time, and a mobile app that keeps you informed. The line-neutral polarity detection is the kind of thoughtful detail that tells you someone actually thought about how this unit gets installed in the real world. For IT pros who want a no-surprises rack UPS with modern remote visibility, this is the one to spec.