This is a true double-conversion online UPS, but it’s built around low-frequency inverter technology—which means it handles tough loads differently than high-frequency units. If you’re running motors, transformers, laser cutters, or anything with a heavy inrush current, this one’s got the muscle to start them and keep them running.
·True double-corversian onine technology
·Output PF-09
·DSP 100%micro controllad
·Srong ovenood capocty,125%for 10minutas/150%for one minute
·Dusl power supply{selectable) +Accept 100%urbalanced lcad
·N+1 parallel rodundant connaction
·Cokd start function
·High efciency-82%
·Ineligert battery cortrol
·Compatble with ganerators
·Good protactions with Fast acting tuses in DC,Fans,
Redundant powersupplies,Temperature.Temperature sen80r8
·Powerful communicatian system(RS232.SNMP.GPRS)
·Large IDC rooms,Industry,bankisecurnes setlemert center,
communicaion networkmanagement certer,semiconductor
product inas,large automabion production,Lasar cuittingmachine highway and railway tunnels mtal halide lamp lighóing system etc.
| Specification \ Model | LP33 20K | LP33 30K | LP33 40K | LP33 60K | LP33 80K | LP33 100K | LP33 120K | LP33 160K | LP33 200K |
| G | eneral | ||||||||
| Capacity | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA |
| Features | Scalable Power/UPS Parallel With Another Of The Same Capacity And Brand/100% Microcontroller/Redundantforced Ventilation/ Immune To Phase Rotation Input/ Dual Input Type Input (Optional) |
||||||||
| Estimated Useful Life | 15 Years | ||||||||
| Efficiency Ac/Ac | Greater Than 92% | ||||||||
| Transfer | 0 Seg. No Transfer Time | ||||||||
| Invertir Technology | True Online (Double Conversion), Inverter Based On Igbt's | ||||||||
| Input | |||||||||
| Voltage () | 460/265 or 480/277 Vac±20% (The Dimensions Could Change On Each Model). | ||||||||
| Frecuency(*) | 50 or 60Hz±10% | ||||||||
| Filers | Emi,Rfi | ||||||||
| Lead Wires (*) | 3 Phases+ Neutral + Ground | ||||||||
| Output | |||||||||
| Voltage (Selectable)() | 460/265 Or 480/277 Vac±1%(The Dimensions Could Change On Each Model). | ||||||||
| Frecuency | 50 or 60Hz±0.1% | ||||||||
| Waveform Type | Sine Wave Generated By The Inverter With High Frequency Pwm | ||||||||
| Harmonic Voltage Distortion T.H.D | <2% For Linear Load/<5% For Non-Linear Load | ||||||||
| Crest Factor | 3:1 | ||||||||
| Power Factor | From 0.9 Leading to 0.9 At Full Load. | ||||||||
| Overload Recovery. | The Ups Autotransferencia | ||||||||
| Isolation Transformer | Dry Type.Voltage 460V/265V or 480/277V | ||||||||
| Voltage Regulation | ± 1% For Balanced Load. | ||||||||
| Overload Capacity () | 125% For 12 Minutes./ 150% For One Minute | ||||||||
| Lead Wires(") | 3 Phases +Neutral+Ground | ||||||||
| Batteries | |||||||||
| Type(*) | 40Pcs For 20 To 200Kva.Sealed And Maintenance Free. Technology Vrla (Valve Regulated Lead Acid) | ||||||||
| Autonomy At Full Load (") | 5 to 15 Minutes. Extended Range Capability. | ||||||||
| Typical Recharge Time. | 4 Hours 90% | ||||||||
| Battery Management. | Auto-Test, Adjustable Battery Transfer Point And Settings Of Alarm. | ||||||||
| Battery Protection. | Breaker Protection.Turn The System Off When The Battery Is Low. Battery Test.Smart Charger. | ||||||||
| Charger | Soft Start To Fuill Load. Current Limiter For Charging Batteries. | ||||||||
| Protections | |||||||||
| Hardware Protection | Breaker (Termomagnetic) For Input, Output, Battery, Bypass, Fast-Acting Fuses In Dc And Bypass, Fan, Powerredundant Temperature Sensors,On-Off Switch, Audible Alarms. |
||||||||
| Bypass | Static,Solid State,Automatic And Uninterrupted Operation Manual For Maintenance. External Bypass (Optional) | ||||||||
| Emergency Breaker. | Local Epo and / or Remote | ||||||||
| Monitoring And Communications | |||||||||
| Front Panel | Lcd Display 4 Rows X 20 Columns For Reading Electrical Parameters. Touchscreen (Optional). Led Mimic. | ||||||||
| Alarms | Audible And Visual Alarms For Non-Normal Conditions. | ||||||||
| Communications | RS232 Serial Port."SNMP-RJ45" For Remote Monitoring (Optional). Gprs Module For Remote Monitoring Viacellular Network (Optional). | ||||||||
| UPS Conditions | |||||||||
| Temperature | 0℃ to 40℃ | ||||||||
| Relative Humidity. | 0'℃ to 95% Noncondensing | ||||||||
| Audible Noise | |||||||||
| Batteries Conditions | |||||||||
| Temperature | 0℃ to 25℃ | ||||||||
| Relative Humidity. | 0 to 95% Noncondensing | ||||||||
| Dimensions And Weights | |||||||||
| Ups Dimensions In Mm (Front"Deep*High) |
535*995*1100 | 645*1070*1320 | 705*1135*1418 | 1160*1043*1900 | |||||
| UPS Weight In"Kg" | 270 | 308 | 380 | 432 | 485 | 608.5 | 650 | 1120 | 1320 |
| *Product Specifications are Subject to Change Without Notice. | |||||||||
This is a true double-conversion online UPS, but it’s built around low-frequency inverter technology—which means it handles tough loads differently than high-frequency units. If you’re running motors, transformers, laser cutters, or anything with a heavy inrush current, this one’s got the muscle to start them and keep them running.
Output power factor is 0.9, and the overload capacity is genuinely useful: 125% for 10 minutes, 150% for a full minute. That’s not just a marketing number—it gives you real breathing room when equipment kicks on or when a temporary overload happens.
It handles 100% unbalanced loads without breaking a sweat, which matters when you’re powering three-phase gear that doesn’t draw evenly across phases. You can also set it up for dual power supply if you need redundant mains inputs, and if you need more capacity or redundancy, N+1 parallel configuration is available.
The DSP-based control is fully digital, so everything stays tight and consistent. Intelligent battery management helps get more life out of the batteries, and it plays nice with generators—no nuisance transfers when the generator sags or surges.
Protections are thorough: fast-acting fuses on DC, redundant fans, temperature sensors, and even protection for the fans themselves. It’s designed to keep running even when conditions get rough.
Cold start is standard, so you can fire it up from battery even if the grid is dead. Efficiency sits above 92%, which is solid for a low-frequency design focused on raw capability rather than chasing the highest efficiency number.
For communication, you’ve got RS232, SNMP, and GPRS options—so whether you’re in a local server room or monitoring a remote site, you can stay connected.
Typical places you’ll see this one: large IDC rooms, industrial automation lines, bank and securities settlement centers, semiconductor production, laser cutting, and even highway or railway tunnel lighting systems where metal halide lamps need clean, stable power.