· Intelligent CPU Control
· Auto restart while AC is recovering
· Boost and buck AVR for voltage stabilization
· Cold start function
· Off-mode charging
· Optional USB or RJ45 port
· Optional LED or LCD panels
· The UPS has mute function when the UPS is in battery mode
· The LCD display can be turned off when the UPS is in AC/Battery mode
| Model | PS500 | PS650 | PS800 | PS1000 | PS1500 |
| Capacity | 500VA / 300W | 650VA / 390W | 800VA / 480W | 1000VA / 600W | 1500VA / 900W |
| INPUT | |||||
| Voltage | 110V / 120 VAC or 220 / 230 / 240 VAC | ||||
| Voltage Range | 81-145VAC or 145-275VAC | ||||
| Frequency | 50 / 60 Hz (Auto Sensing) | ||||
| OUTPUT | |||||
| Voltage | 110V / 120 VAC or 220 / 230 / 240 VAC | ||||
| Voltage Range | ±10% | ||||
| Frequency Range(Battery Mode) | 50 / 60 ±1Hz | ||||
| Transfer Time | 4 - 6ms | ||||
| Wave Form(Battery Mode) | Simulated Sine Wave | ||||
| BATTERY | |||||
| Battery Model & Quantity | 12V/4.5AH * 1PC | 12V/7AH * 1PC | 12V/9AH * 1PC | 12V/9AH * 1PC or 12V/7AH * 2 PCS |
12V/9AH * 2 PCS |
| Charge Time | 6-8 hours recharge time | ||||
| PROTECTION | |||||
| Full Protection | Discharge, Short circuit and overload protection | ||||
| INDICATORS | |||||
| LCD Display | AC mode, Battery mode, Load level, Battery level, Input voltage, Output voltage, Overload and low battery | ||||
| Line Mode | Green lighting | ||||
| Battery Mode | Red lighting | ||||
| Battery Charge Mode | Yellow lighting | ||||
| ALARM | |||||
| Battery Mode | Sounding every 4 seconds | ||||
| Low Battery | Sounding every second | ||||
| Overload | Sounding every second | ||||
| Fault | Continuously sounding | ||||
| INTERFACE | |||||
| Interface | Support windows XP/Vista, Windows 7/8, Linux, Unix, and MAC | ||||
| Communication Interface | USB / RJ45 Port(Optional) | ||||
| ENVIRONMENT | |||||
| Humidity | 0-90%RH @0-40℃(Non-condensing) | ||||
| Noise Level | Less than 40dB | ||||
| Dimension(mm) | 310*95*130 | 320*95*130 | 315*95*130 | 315*120*170 | 315*120*170 |
| N.W.(kg) | 3.9 | 5.1 | 5.6 | 9.8 | 11.8 |
| Note : Product Specification are Subject to Change Without Further Notice. | |||||
Pacific Star Series Line Interactive UPS: Intelligent, Automated Power Protection for the Modern Workspace
In an era where technology is expected to operate with minimal human intervention, the power protection infrastructure that underpins critical equipment should adhere to the same principle. The Pacific Star Series Line Interactive UPS embodies this philosophy of intelligent automation. Built around a sophisticated CPU-controlled architecture, this UPS transcends the basic functionality of battery backup to deliver a truly autonomous power management experience. It is engineered for professionals, small business owners, and home office users who demand reliable protection for their computers, networking gear, and security systems—without the burden of constant monitoring or manual intervention.
Intelligent CPU Control: The Brain Behind the Brawn
The defining characteristic of the Pacific Star Series is its intelligent CPU control system. Unlike simpler analog or microcontroller-based UPS designs that rely on fixed thresholds and predefined responses, the Pacific Star's central processor continuously evaluates multiple operational parameters—input voltage, output load, battery status, and internal temperature—to make real-time decisions that optimize both protection and user convenience.
This computational intelligence manifests most visibly in the unit's approach to power event management. When the utility grid experiences a disturbance, the Pacific Star does not simply react; it responds with a context-aware sequence of actions designed to maximize uptime and minimize disruption.
Automated Restart: Unattended Recovery After Extended Outages
One of the most practical yet frequently overlooked capabilities of the Pacific Star Series is its automatic restart functionality. In scenarios where a power outage outlasts the UPS battery capacity, the unit will eventually shut down to protect its internal cells from deep discharge damage. When utility power is subsequently restored, a conventional UPS would remain in a powered-off state, requiring a manual button press to resume operation.
The Pacific Star eliminates this manual step entirely. Once AC input power is reestablished, the unit automatically restarts and resumes supplying power to connected equipment. This feature is invaluable in several deployment scenarios:
Remote or Unattended Locations: For network closets, security camera installations, or small branch offices without onsite IT personnel, automatic restart ensures that equipment comes back online without requiring a site visit.
After-Hours Retail Environments: POS terminals and security systems in retail locations can recover from overnight outages before staff arrives for the next business day.
Home Offices During Travel: Professionals who travel for work can rest assured that their home network and remote access infrastructure will self-restore following a power event.
This level of automation transforms the Pacific Star from a simple battery backup into a truly self-sufficient power management appliance.
Automatic Voltage Regulation (AVR): Clean Power Without Battery Drain
The Pacific Star Series incorporates a robust Automatic Voltage Regulation (AVR) system that actively conditions incoming utility power to protect connected equipment from the cumulative stress of voltage fluctuations. When the grid delivers power that is too low (a brownout condition), the AVR circuit engages to boost the voltage to an acceptable level. Conversely, when incoming voltage is too high (a swell or over-voltage condition), the AVR circuit trims or bucks the excess voltage.
Critically, this voltage correction is accomplished without drawing any energy from the internal battery. By reserving battery capacity for genuine blackout scenarios rather than depleting it during routine voltage corrections, the Pacific Star Series preserves battery health and extends operational lifespan. Connected equipment—whether a personal computer, a printer, or a security system DVR—receives steady, clean power even when the utility grid fails to cooperate.
Cold Start Functionality: Power When You Need It, Regardless of Grid Status
An additional layer of operational flexibility is provided by the Pacific Star's cold start function. This capability allows the UPS to be powered on and deliver battery power to connected loads even when there is no utility power present at the input.
Diagnostic and Testing Procedures: Technicians can verify UPS operation and connected equipment functionality at the bench without requiring access to an AC outlet.
Temporary Field Power: In construction, event management, or remote field applications, the Pacific Star can serve as a temporary AC power source for low-power equipment using only its internal battery reserves.
Emergency Preparedness: During extended outages where a generator is being deployed, the UPS can provide interim power to critical devices while the generator is being set up and stabilized.
Off-Mode Charging: Maintaining Battery Readiness Without Powering the Load
The Pacific Star Series supports off-mode charging, a subtle but meaningful convenience feature. When the UPS is connected to AC utility power but switched off via its front panel, the internal charging circuit remains active. This allows the battery to be fully charged and maintained in a state of readiness without supplying power to connected equipment.
This capability is particularly valuable in scenarios where equipment is deployed in phases, where a UPS is being stored as a spare, or where connected devices are not yet installed. The unit can be plugged in and left to charge its battery, ensuring that when it is eventually called into service, it is fully prepared to deliver its rated backup runtime.
Flexible Communication and Monitoring Ports
Effective power management requires visibility, and the Pacific Star Series provides flexible options for connectivity and monitoring. Users may select between USB and RJ45 communication ports based on their specific integration requirements.
USB Connectivity: Enables direct connection to a host computer running standard operating system power management software. This allows for automated graceful shutdown sequences and basic UPS status monitoring.
RJ45 Network Port: Provides surge-protected pass-through for Ethernet connections, safeguarding network equipment from voltage spikes that may travel over data cabling. This port also supports network-based monitoring on select configurations.
These connectivity options empower users to integrate the Pacific Star into their broader IT ecosystem, ensuring that power events are logged, alerts are generated, and automated responses are executed without human intervention.
Customizable Display and Acoustic Management
The Pacific Star Series distinguishes itself through an uncommon attention to user experience, particularly regarding display configurability and acoustic management. Recognizing that a UPS is often deployed in occupied spaces—under a desk, beside a workstation, or within a quiet home office—the Pacific Star offers several features designed to minimize disruption.
Display Options: LED or LCD
Users may select either a straightforward LED indicator panel or a more detailed LCD display based on preference and budget. The LCD option provides granular visibility into input/output voltage, load percentage, and battery capacity.
Audible Alarm Mute in Battery Mode
During a power outage, the characteristic beeping of a UPS can become an unwelcome distraction. The Pacific Star Series allows users to mute the audible alarm while the unit is operating in battery mode, preserving a quiet environment while still maintaining full backup power protection. This feature is particularly appreciated in home offices, recording studios, or any setting where acoustic tranquility is valued.
LCD Backlight Control
For environments where light pollution is a concern—such as a dark server closet, a bedroom home office, or a video editing suite—the Pacific Star Series offers granular control over the LCD backlight. Users may configure the display to turn off completely while the UPS is operating on either AC or battery power. This eliminates unnecessary glow and distraction, keeping the workspace visually clean and free from nuisance illumination.
Broad Application Compatibility
The Pacific Star Series is engineered to provide reliable protection for a diverse array of equipment commonly found in residential, commercial, and small office environments. Its line interactive topology with AVR makes it particularly well-suited for:
Personal Computers and Workstations: Safeguarding desktop systems from data loss and hardware stress caused by power anomalies.
Printers and Multifunction Devices: Protecting sensitive printer control boards and preventing interrupted print jobs.
Point-of-Sale (POS) Terminals: Ensuring transaction continuity and data integrity in retail and hospitality settings.
Security Systems and DVR/NVR Units: Maintaining surveillance coverage and recording integrity during grid disturbances.
Fax Machines and Communication Devices: Preserving connectivity for legacy and essential communication equipment.
Modems, Routers, and Network Switches: Keeping internet and local network connectivity alive during brief power interruptions.
This broad compatibility ensures that the Pacific Star Series delivers value across a wide spectrum of applications, from the home office to the small business network closet.
Certification and Assurance
The Pacific Star Series is manufactured under rigorous quality control protocols and carries the necessary international certifications, including CE compliance. This certification provides independent verification that the product meets established standards for safety, electromagnetic compatibility, and environmental responsibility. Each unit is further supported by a standard 24-month warranty, reflecting UPSEN's confidence in the durability and long-term reliability of the Pacific Star Series.
Conclusion: Intelligent Protection That Stays Out of Your Way
The Pacific Star Series Line Interactive UPS represents a thoughtful evolution in the category of entry-to-mid-level power protection. By embedding intelligent CPU control, automated restart logic, cold start capability, and user-configurable acoustic and visual management features, it delivers a user experience that is both refined and remarkably unobtrusive.
This is a UPS designed to operate in the background—silent, dark, and autonomous—intervening only when necessary and restoring normal operation without demanding attention. For professionals, small business owners, and home users who value reliability without complexity, the Pacific Star Series offers a compelling blend of advanced automation and practical convenience. It is power protection that works intelligently, so you do not have to.